Charging stations LS-4 meet the stringent requirements for devices installed in public areas. Communication – LAN and/or 4G network
Supply AC / charging |
1-phase network |
3-phase network |
Working charging current range (50 Hz) |
6...16 A, 6...32 A |
6...32 A |
Charging power |
2 x 3,7 kW |
2 x 11 kW or 2 x 22 kW |
Installation in power grid |
TN-S, TT, IT system |
|
Charging mode |
Mode-3 |
|
Cover protection category |
IP 44 (optional versions IP 54) |
|
Degree of mechanical strength |
IK 10 |
|
Operating temperature |
-25 do 40°C |
|
Weight: |
25 kg (2 x socket) |
Recommended places of installation: