Surge arresters for AC installations

, New products

Surge arresters for AC installations

Surge arresters for AC installations provide effective protection for electrical equipment against sudden voltage spikes. Today's electronic devices are advanced technologies that require special protection. Lightning discharges, network failures or overloads can damage delicate integrated circuits, leading to costly failures, data loss and even life-threatening situations. This is why protection in the form of surge arresters is essential! They are the ideal solution for both domestic and industrial installations.

The most important properties of surge arresters of RSP series  

  • Available types: T1T2, T2 and T2T3
  • Configuration options: 1-, 2-, 3-, and 4-pole versions
  • Designed in compliance with IEC 61643-31:2018
  • Response time ≤ 100 ms
  • Maximum discharge current: 10–60 k
  • Protection modes: N-PE and L-N
Surge arresters series  RSP-T1T2-AC 7
  • Class I+II/ Type 1+2/ B+C
  • Impulse discharge current Iimp - 7 kA/pole
  • Number of poles 1 to 4
  • Max. discharge current Imax 50 kA/pole
  • Nom. discharge current 20 kA
  • Response time ≤ 100 ns
  • Voltage protection level ≤ 1,5 kV
  • Max. continuous operating voltage 275 V AC (with NPE 255 V AC)
    More

RSP-T1T2-AC7_3-NPE

Surge arresters series RSP-T1T2-AC 12,5
  • Class I+II/ Type 1+2/ B+C
  • Impulse discharge current Iimp - 12,5 kA/pole
  • Number of polesod 1 to 4
  • Max. discharge current Imax 60 kA/pole
  • Nom. discharge current 30 kA
  • Response time ≤ 100 ns
  • Voltage protection level ≤ 2 kV (with NPE ≤ 1,5 kV)
  • Max. continuous operating voltage 275 V AC (with NPE 255 V AC)
    More

RSP-T1T2-AC12,5_3P

Surge arresters series RSP-T2-AC
  • Class II/ Type 2/ C
  • Number of poles 1 to 4
  • Max. discharge current Imax - 40 kA/pole
  • Nom. discharge current - 20 kA/pole
  • Response time≤ 25 ns
  • Voltage protection level ≤ 1,5 kV
  • Max. continuous operating voltage 275 V AC (with NPE 255 V AC)
    More

RSP-T2-AC_3-NPE

Surge arresters series RSP-T2T3-AC
  • Class II+III / Type 2+3 / C + D
  • Number of poles1 to 4
  • Max. discharge current Imax - 20 kA/pole
  • Nom. discharge current - 10 kA/pole
  • Response time ≤ 25 ns
  • Voltage protection level ≤ 1,2 kV
  • Max. continuous operating voltage 275 V AC (with NPE 255 V AC)
    More

RSP-T2T3-AC_3P